Single Phase Submersible Pump Controller Panel Box

Product Details
Customization: Available
After-sales Service: 2 Year
Warranty: 2 Year
Still deciding? Get samples of US$ 75/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T, D/P, PayPal, Western Union
OEM/ODM Availability
Yes
  • Single Phase Submersible Pump Controller Panel Box
  • Single Phase Submersible Pump Controller Panel Box
  • Single Phase Submersible Pump Controller Panel Box
  • Single Phase Submersible Pump Controller Panel Box
  • Single Phase Submersible Pump Controller Panel Box
  • Single Phase Submersible Pump Controller Panel Box
Find Similar Products

Basic Info.

Model NO.
30Y1-11000D
Driving Type
Motor
Material
ABS Plastic
Assembly
Liquid Pumps
Power
Electric
Start Up
Start Pump
Application
Submersible Pump, Clarified Water Pump, Sewage Pump, Oil Transfer Pump, Centrifual Pump
Industry
Pump Control
Performance
Automatic Pump
Voltage
380V-415VAC or 220V-240VAC
Rated Power
1.1-11kw
Pump No.
Single Pump Control
Control Mode
Water Level/Pressure/Time/Water Supply/Drainage
Protections
Overload/Noload/Overvoltage/Undervoltage.....
Applications
Home/Commercial/Industrial
Business Type
Manufactuer/Factory
R&D Capacity
OEM/ODM/Own Brand
City
Wenzhou
Transport Package
Carton
Specification
33.5x14.5x30.6
Trademark
JNN
Origin
China
HS Code
9032899099
Production Capacity
15000

Packaging & Delivery

Package Size
38.00cm * 19.00cm * 35.00cm
Package Gross Weight
4.000kg
Lead Time
7 days (1 - 10 Pieces)
To be negotiated ( > 10 Pieces)

Product Description

Single Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxProduct Description
30Y series intelligent water pump controller, JNN brand high-end product line for 2024.It's core control panel is equipped with updated microcomputer chip, optimized programming language, and added new protection functions to deal with emergency circuit crises.Source manufacturer, professional team, mature production line.
WHAT YOU SEE IS WHAT YOU GET.
Pump No. Rated Voltage Rated Power Model Number
Single Pump Control 380V-415VAC
Three Phase
0.75-4KW 30Y1-4000D/380V3PH
1.1-7.5KW 30Y1-7500D/380V3PH
1.1-11KW 30Y1-11000D/380V3PH
2.2-15KW 30Y1-15000D/380V3PH
220V-240VAC
Three Phase
0.75-4KW 30Y1-4000D/220V3PH
1.1-7.5KW 30Y1-7500D/220V3PH
1.1-11KW 30Y1-11000D/220V3PH
220V-240VAC
Single Phase
0.75-4KW 30Y1-4000D/220V1PH
1.1-7.5KW 30Y1-7500D/220V1PH
1.1-11KW 30Y1-11000D/220V1PH
Two Pump Control 380V-415VAC
Three Phase
0.75-4KW 30Y2-4000D/380V3PH
1.1-7.5KW 30Y2-7500D/380V3PH
1.1-11KW 30Y2-11000D/380V3PH
2.2-15KW 30Y2-15000D/380V3PH
220V-240VAC
Three Phase
0.75-4KW 30Y2-4000D/220V3PH
1.1-7.5KW 30Y2-7500D/220V3PH
1.1-11KW 30Y2-11000D/220V3PH
220V-240VAC
Single Phase
0.75-4KW 30Y2-4000D/220V1PH
1.1-7.5KW 30Y2-4000D/220V1PH
1.1-11KW 30Y2-4000D/220V1PH

Main Features
Overflow alarm
Rated power setting
ON/OFF time delay
Parameter settings at fingertips
Water level control by level probes or float switch
Pressure control by pressure gauge or pressure switch
LCD screen displaying current,voltage,water level and other pump status
Accumulative pump run time
Latest 10 pump failures record and display
Automatic restart after pump failure recovery
RS-485 communication(optional)

Parameter Setting
P00 --- Retore factory setting
PP0 --- Rated power current setting
P01 --- Over-current protection percentage setting,100%-170% adjustable,default 135%.
P02 --- Dry run current protection percentage setting,50%-100% adjustable,default 70%.
PPP --- Pump stalled protection percentage setting,100%-200% adjustable,default 170%.
P05 --- No load restart time setting,0-720 minutes adjustable,default 30 munites.P06--- Two pump alternation time
setting,0-720minutes adjustable.
P07 --- Over-voltage setting.
P08 --- Under-voltage setting.
P09 --- Screen backlight ON time setting,0-999 minutes adjustable,default 30 minutes.
P12 --- No load protection trip delay time setting,0-600 seconds adjustable,default 0 second.
P13 --- Overload protection trip delay time setting,0-600 seconds adjustable,default 0 second.
P14 --- ON time delay,1-60 seconds adjustable, default 0 second.
P15 --- OFF time delay,1-60 seconds adjustable,default 0 second.
P16 --- Self check for anti-rust time setting,24-240hours adjustable,default 72 hours.
P17 --- Overload/over-current retart time setting,0-10 minutes adjustable,default 0 minute.
P18 --- Overflow buzzer alarm time setting,0-99 seconds adjustable,default 0 second.
P19 --- Phase loss retart time setting,0-99 minutes adjustable,default 0 minute.
P20 --- Overvoltage-undervoltage restart time setting, 0-999 seconds adjustable,default 0 second.
P21 --- Phase reversal protection setting
P22 --- Three phase unbalance percentage,0-500% adjustable,default 0.
Single Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel Box
Single Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel BoxSingle Phase Submersible Pump Controller Panel Boxpump down control;pump discharge control;pump down control system;pump displacement control;alternating pump control;pump engine controller;well pump electrical control box;electric pump control panel;eaton pump control panel;ekwb pump control;pump controller for water tank;pump controller for irrigation;pump controller franklin;pump flow control methods;pump flow control;pump fan control;pumps flood control;automatic pump control failure;automatic pump control failure light on;automatic pump control function;automatic pump control haitun;pump controller ;pump in controller;pump control logic;pump control low water cut off;pump local control panel;pump local control station;pump level control;pump load control;water pump control location;pump control and low water cut-off;pump measure control;pump motor control panel;pump motor control;pumping machine control box;pumping machine control box price;pump motor controller;pump off control;pump on control box;pump control panel manufacturer;pump control panel price list;pump control plc;pump control price;pump control panel specification;pump control room;pump control remote;pump remote control;pump control soft starter;pump station control panel;control pump station location

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier