Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Task: | Program |
| Structure: | Closed-Loop |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Type | VFD Constant | ||
| Model | LZ001-2S0075 | LZ001-2S015 | LZ001-2S022 |
| Rated Power | 0.75kw | 1.5KW | 2.2KW |
| Rated Input Voltage | 220V±15%/50Hz or 60Hz | ||
| Qty.of Controlled Pump | Single pump | ||
| Display | LCD display | ||
| Signal Transmission Mode | Level float switch Level probe Pressure switch Electric contact pressure gauge |
||
| Water Level Indication | High/Middle/Low | ||
| Max.Control Distance | ≤2000m without strong electric and electromagnetic fields | ||
| Over/under-voltage Range | 176-264V(adjustable) | ||
| Protections | Pump stalled protection Dry run protection Over-load protection Under-voltage protection Over-voltage protection Open phase protection Short circuit protection |
||
| Main Functions | Time setting Fault detection Anti-rust inspection Automatic restart after power recovery |
||
| Product Size | 320x220x125mm | ||
| Working temperature Working humidity Degree of protection Install position |
-25ºC-- +55ºC 20%--90%RH, no drips concreted IP54 Wall mounting |
||