Items | Specification | |
Basic indicators | Adapt motor | Three phase induction asynchronous motor,three phase permanent magnet synchronous motor |
Control model | V/F Control,open-loop vector control | |
Maximum output | 600.00Hz(Customizable) | |
Speed range | VF control 1:50,open-loop vector control 1:100 | |
Practical functions | Terminal delay | The input and output terminals of the switch can be individually set with corresponding delay settings |
Simple PLC | Realize multi-stage speed operation through built-in simple PLC or switch input terminals | |
Built-in PID | Convenient implementation of process closed-loop control | |
Count | It can count pulse signals(0-500Hz) and achieve counting control with switch output terminals; The count value can also be converted into length for display and control | |
Customize input and output | Can implement parallel custom input and series custom input separately,and generate corresponding custom output functions | |
Peripheral terminals | Reference power supply | 10V/30mA,generally used for simulating input signal power supply |
Control power supply | 24V/300mA ,generally used for switch input and output terminal signal power supply | |
Analog input | Standard configuration includes 2 analog inputs,with the option to choose between voltage 0-10V or current signal input 0-20mA | |
Analog output | Standard configuration includes 1 analog output,0-10V/0-20mA | |
Switch input | Standard configuration includes 7 multi-functional switch inputs (including 1 high-speed pulse input) | |
Switch output | Standard configuration includes 2 relay outputs,with the option to expand to 9 more | |
Communication terminal | Standard configuration includes 2 RS485 communication channels | |
Usage environment | Place of use | No direct sunlight,no corrosive gases,flammable gases,oil mist,water vapor,dripping,salt,etc |
Altitude | Below 1000m;If the height is higher than 1000m,the rating will be reduced.For every 100m increase,the rating will be reduced by 1% | |
Temperature | -10°C—+40°C(The ambient temperature is between 40°C and 50°C,the rating will be reduced for use) | |
Humidity | 5—95RH(No condensation) | |
Vibration | Below 5.9m/s2(0.6g) | |
Storage temperature | -20°C—+60°C | |